Server Technology C-16HF1-L30 Rack Mount 2U Fail-Safe Transfer Switch
$ 105.07
- Description
- Size Guide
Description
Server Technology C-16HF1-L30 Rack Mount 2U Fail-Safe Transfer Switch.Server Technology - C-16HF1-L30 - Server Technology Sentry C-16HF1-L30 Automatic Transfer Switch
Technical Specs
• Product Type: Automatic Transfer Switch
• Product Type: Automatic Transfer Switch
• Input Voltage: 110 V AC
• Manufacturer Part Number: C-16HF1-L30
• Manufacturer Website Address: http://www.servertech.com
• Current: 30 A
• Form Factor: Rack-mountable
• Manufacturer: Server Technology, Inc
• Product Model: C-16HF1-L30
• Product Name: Sentry C-16HF1-L30 Automatic Transfer Switch
• Product Line: Sentry
• Brand Name: Server Technology
• Receptacles: 16 x NEMA 5-20R
• Brand Name: Server Technology
• Height: 3.5"
• Width: 17"
• Depth: 14"
• Environmentally Friendly: Yes
• Environmental Certification: WEEE
• Environmental Certification: RoHS
Product Description
Server Technology C-16HF1-L30 Metered ATS Specifications:
Input Connector - (2) NEMA L5-30P
Input Cords - 10ft, 3-conductor, 10AWG (hardwired)
Input Current Rating - ≤ 24A (30A max)
Input Voltage Rating - 100V-120V L-N nominal, 60Hz
Outlets - (16) NEMA 5-20R
Output Current Rating - ≤ 16A (20A max)
Output Usable Power - 2.8kW
Output Max Power - 3.6kW @ 120V
Features:
Type - Metered (Not Networked)
Input Current Monitoring - Yes
Form Factor - 2U, Horizontal Mount (Brackets Included)
Branch Circuit Protection - Internally fused
Input Current LEDs - One per input feed
Expansion Unit to Share One IP Address - NA
Temperature/Humidity Sensors - No
Phase Synchronization Required? - No
The Server Technology C-16HF1 Fail-Safe Transfer Switch (FSTS) provides fail-over redundancy to single or dual power supply servers and network devices. Exclusive to the Fail-Safe Transfer Switch is its ability to carry loads on both the A and B circuits during normal operation.
Unlike a common automatic transfer switch, the Fail-Safe unit is unique in that the "A" in-feed routinely powers half the outlets, and the "B" in-feed routinely powers the other half. However, if either in-feed goes down, the other powers all outlets. This "Fail-Safe" method has several advantages compared to a standard ATS. A standard ATS contains two-in-feeds, but runs all outlets from just one source, with the secondary source only being used once an outage occurs. The Server Technology design does not prohibit load balancing between the two supplied circuits which results in less heat and a lower voltage drop compared to the same load existing on just one source. Only when an outage occurs on one of the two sources will the entire load be applied to a single source.
Metered (not networked)
Digital True RMS input current at ±10% and 0.1 amp resolution (to 9.9 amps measurement, 1 amp at > 10 amp).
Transfer Rate
Power transfer in 10-16 milliseconds maximum
Input Power
Dual Power Source Input
Each input supplies power to half of the outlets
Input power cables for NEMA L5-30P, L6-30P, IEC 60390/C19
Voltage Range
100-120V (configurable)
Inputs must have same voltage
Indicator LEDs
Monitor load per circuit
UPS Compatibility
Transfer Switch is compatible with a UPS that provides a sin wave AC output waveform.
Environmental Requirements
Operating: 32° to 104°F (0° to 40°C) Temperature - 8% to 90% non-condensing Humidity
Storage: -40° to 185°F (-40° to 85°C) Temperature - 8% to 90% non-condensing Humidity
Standards
cTUVus – UL 60950-1:2007
CAN/CSA 22.2 No. 60950-1-07
FCC Class A, Part 15
RoHS/WEEE
Branch Circuit Protection
Compliant to UL 60905-1
UL248 listed fuses, 20A
Two (2) branches per input
Current Rating: <16A; Interrupt rated at 100kAIC